A–14

Specifications and Supplemental Information

Encoder Interface Wiring

Option L4/L4E & L7E Wiring

Option L4/L4E - Contact Closure Interface Board Requirements

Contacts must be capable of operating at 10 mA current levels
without signal degradation. Reed type input devices are recom-
mended.

The L4/L4E option is compatible with the following Allen-Bradley
PLC

modules:

• 1771-OYL

• 1771-OZL

Option L7E - Contact Closure Interface Board Requirements

Circuits used with Option L7E must be capable of operating with
low = true logic. In the low state, external circuits must be capable of
a sinking current of approximately 10 mA to pull the terminal voltage
low to 3.0V DC or less. In the high state, external circuits must let the
terminal voltage rise to a voltage of 4.0-5.0V DC. Reed type input
devices are recommended.

The L7E option is compatible with the following Allen-Bradley
PLC

modules:

• 1771-OYL

• 1771-OZL

L4/L4E

L7E

19

20

21

22

23

24

25

26

27

28

29

30

31

32

A

A

ENC
RET

ENC
12V

33

34

35

36

Typical

Typical

Isolated
+5V

Isolated
Ground

0.1

µf

0.1

µf

0.1

µf

10.7k

470

470

12V

681

100

90.9

5V

JP4

IGND

10.7k

TB3

19

20

21

22

23

24

25

26

27

28

29

30

31

32

A

A

ENC
RET

ENC
12V

33

34

35

36

Typical

Typical

Isolated
+5V

Isolated
Ground

0.1

µf

0.1

µf

0.1

µf

10.7k

470

470

12V

681

173

576

5V

J1/J2

IGND

10.7k

TB3

Current

Limit

Feedback

0.5A

0.001

B

B

2200pf

255