Page 128: Start owner, Jog owner, Reference owner, Accel owner

6–46
Programming
Owners
This group of parameters contains binary information to display which group of adapters
are issuing control commands.
Each Owner Parameter contains a bit for each adapter.
The drive will set an adapter’s bit to “1” when that adapter
is issuing a logic command and to “Zero” when no com-
mand is being issued.
A Status description (bit ENUM) is displayed on line 1 (ex-
cept Series A HIMs below version 3.0).
[Stop Owner]
This parameter displays which adapters are presently is-
suing a valid stop command.
Parameter Number
102
Parameter Type
Read Only
Units
Display Drive
“0” 0
Stop Input Not Present
“1” 1
Stop Input Present
[Direction Owner]
This parameter displays which adapter currently has ex-
clusive control of direction changes.
If [Freq Select 1] or [Freq Select 2] is set to “Analog In 0”
and an Analog Option Board with bipolar input (LA6, LA7)
is installed, that input (designated “Analog In 0”) will have
exclusive ownership of direction. Bit 7 of [Direction Mask]
must not be set to “0” and no other device can have claimed
ownership of direction (i.e. TB3 - Run Reverse). If either
condition is true, a fault will be issued.
Parameter Number
103
Parameter Type
Read Only
Units
Display Drive
“0” 0
Non-Owner
“1” 1
Current Owner
[Start Owner]
This parameter displays which adapters are presently is-
suing a valid start command.
Parameter Number
104
Parameter Type
Read Only
Units
Display Drive
“0” 0
Start Input Not Present
“1” 1
Start Input Present
[Jog Owner]
This parameter displays which adapters are presently is-
suing a valid jog command.
Parameter Number
105
Parameter Type
Read Only
Units
Display Drive
“0” 0
Jog Input Not Present
“1” 1
Jog Input Present
[Reference Owner]
This parameter displays which adapter currently has the
exclusive control of the selection of the command frequen-
cy source.
Parameter Number
106
Parameter Type
Read Only
Units
Display Drive
“0” 0
Non-Owner
“1” 1
Current Owner
[Accel Owner]
This parameter displays which adapter has exclusive con-
trol of selecting [Accel Time 1] or [Accel Time 2].
Parameter Number
107
Parameter Type
Read Only
Units
Display Drive
“0” 0
Non-Owner
“1” 1
Current Owner
TB3
Adapter 1
Adapter 2
Adapter 3
Adapter 4
Adapter 5
Adapter 6
Not Used
Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0
Owners Display