Using the up/down counter function, Using the up/down counter function -14 – Rockwell Automation 1336E IMPACT Adjustable Frequency AC Drive User Manual V 1-4.XX User Manual
Page 184

10-14
Using the Function Block
Figure 10.17
Maximum/Minimum Function Block
Using the Up/Down Counter
Function
The up/down counter function lets you increment or decrement a
value. The up/down counter function block is shown in Figure 10.18.
200
Func 1 Eval Sel
0
198
Function In1
199
Func 1 Mask/Val
Enter: 0 This value is not used.
Maximum/Minimum
Function Block
203
Func 2 Eval Sel
0
201
Function In2
202
Func 2 Mask/Val
Enter: 0 This value is not used.
212
Function Sel
10
In1, In2 < [min] Out1
In3: 0: min —> Out1
In1
In2
213
Function
Output 1
206
Func 3 Eval Sel
0
204
Function In3
205
Func 3 Mask/Val
Enter: 0
Enter: 0 This value is not used.
In3
Out1
96
An In 1 Value
98
An In 1 Offset
97
An In 1 Scale
= 0
= 2
137
SP An In2 Value
136
SP An
In2 Sel
138
SP An
In2 Scale
= 6
= 1
...
Gateway
+4096
+4096
+4096
0–10V
Enter 0 for parameters 207 through 211
as these parameters are not used for this
function block.
= 0
29
Speed
Ref 1