185 notch filtr freq, 186 notc h filtr q – Rockwell Automation 1336E IMPACT Adjustable Frequency AC Drive User Manual V 1-4.XX User Manual
Page 253

Parameters
11-55
185
Notch Filtr Freq
Use Notch Filtr Freq to set the center frequency for an optional
2-pole notch filter. To enable the notch filter, you need to set Fdbk
Filter Sel (parameter 65) to 4.
1 Notch Filtr Freq was added in Version 2.xx.
Parameter number
File:group
Control:Speed Feedback
Parameter type
linkable destination
Display
x.x Hz
Factory default
135.0 Hz
Minimum value
5.0 Hz
Maximum value
135.0 Hz
Conversion
8 = 1
Refer to the Torque Reference Overview in Appendix B, Control
Block Diagrams, for more information about the notch filter.
186
Notch Filtr Q
Use Notch Filtr Q to set the quality factor, or Q, for the 2-pole
notch filter. To enable the notch filter, you need to set Fdbk Filter
Sel (parameter 65) to 4.
1 Notch Filtr Q was added in Version 2.xx.
Parameter number
File:group
Control:Speed Feedback
Parameter type
linkable destination
Display
x
Factory default
50
Minimum value
2
Maximum value
500
Conversion
1 = 1
Refer to the Torque Reference Overview in Appendix B, Control
Block Diagrams, for more information about the notch filter.