5-2
Using the L Option
What is the L Option?
The L Option is a plug-in option card that provides control inputs to
the drive. The six versions of the L Option are:
Important: We do not recommend using an L4E, L5E, or L6E with
the 1336 IMPACT drive.
This option:
Is a:
Can you attach
an encoder?
This option is compatible with these Allen-Bradley PLC
modules:
L4
1
Contact closure interface
No
1771-OYL, 1171-OZL
L7E
2
Contact closure interface
Yes
L5
+24V AC/DC interface
No
1771-OB, 1771-OB16, 1771-OBB, 1771-OBD,
1771-OBN, 1771-OQ, 1771-OQ16, 1771-OYL,
1171-OZL
+24V AC/DC interface
Yes
L6
115V AC interface
No
1771-OA, 1771-OAD
3
, 1771-OW, 1771-OWN
115V AC interface
Yes
1 The L4, L5, and L6 options each have nine control inputs. You can select the function of each input through an L Option mode, which is
covered later in this chapter.
2 The L7E, L8E, and L9E options are similar to the L4, L5, and L6 options with the addition of encoder feedback inputs.