Appendix a, Specifications, Chapter objectives – Rockwell Automation 1336E IMPACT Adjustable Frequency AC Drive User Manual V 1-4.XX User Manual
Page 327: Appendix

Appendix
A
Specifications
Chapter Objectives
Appendix A provides the specifications for the 1336 IMPACT drive.
Specifications
The following table shows the specifications for the 1336 IMPACT
drive:
This topic:
Starts on page:
Specifications
Input/output ratings
Cable and wiring requirements
Software block diagrams
This category:
Has these specifications:
Environmental
Ambient operating temperature
IP00, Open: 0 to 50
° C (32 to 122° F)
IP20, NEMA Type 1 Enclosed: 0 to 40
° C (32 to 104° F)
IP65, NEMA Type 4 Enclosed: 0 to 40
° C (32 to 104° F)
Storage temperature (all constructions)
-40 to 70
° C (-40 to 158° F)
Atmosphere
Important: Drive must not be installed in an area where the ambient atmosphere contains
volatile or corrosive gas, vapors or dust. If the drive is not going to be installed for a period of
time, it must be stored in an area where it will not be exposed to a corrosive atmosphere.
Relative humidity
5 to 95% non-condensing
Altitude
1000m (3300 ft) without derating
Shock
15g peak for 11 ms duration (+1.0 ms)
Vibration
0.152 mm (0.006 inches) displacement. 1g peak