Installation and Hookup
4-33
Publication 999-122 - January 1997
Plug the terminal block into the channel (A or B) on the RIO adapter 
which you wish to use for RIO communications. Either channel can be 
used–the selection is made in the Application Setup Menu. See the 
Setup section of this manual for information on configuring RIO 
operation.
Connecting AxisLink 
(Optional)
IMC-S/23x-L and IMC-23x-RL models include AxisLink, which 
allows linking multiple IMC S Class controllers and ALECs (AxisLink 
Encoder Converter modules) together so that axes on one controller or 
ALEC can be used as master axes for electronic gearing and cams on 
other controllers. On these models, the AxisLink cable is connected to 
channel A of the AxisLink option using a 3-terminal pluggable terminal 
block on the AxisLink option front panel. The AxisLink option front 
panel is shown below.
Important: All nodes on the same AxisLink network should be
operated at the same servo update rate.
ALECs cannot currently operate in extended length mode.
!
ATTENTION: Even though the front panel of the 
AxisLink option is identical to the RIO Adapter front 
panel, the two options are not interchangeable. Do not 
mix RIO and AxisLink connections or neither system 
will work properly.