5-18
Understanding IMC-S/23x Setups
Publication 999-122 - January 1997
The operator interface can be configured to operate off either serial 
port. If you are using DH-485 or your application uses serial port B for 
another function (such as the master controller in multidrop), answer 
A to the 
Operator Interface Serial Port?
question to
place the operator interface on serial port A. Since direct command 
mode always appears on serial port A, if you configure the operator 
interface for use on serial port A also, use the ESC (Escape) key to 
toggle between these two modes. 
If you are using a dumb terminal or terminal emulation software on a 
computer which automatically inserts Line Feed characters whenever 
a Carriage Return character is received as an operator interface, answer 
NO
to the
Linefeed Insertion?
question to turn off the extra line
feed normally generated by the IMC-S/23x. You can tell that your 
terminal is generating its own linefeeds if the operator interface display 
is double spaced. 
Do not answer
NO
to the
Carriage Return Insertion?
question otherwise erratic behavior of the operator interface 
may result. 
The setup and application passwords may be changed from their default 
values by entering the desired three character string in response to the 
appropriate question. The passwords are not case-sensitive, so either 
upper or lower case characters may be used for the passwords. If you 
change the passwords, do not forget them or you will be prevented from 
re-entering the setup menus!
Editing the Runtime 
Display Configuration
After completing the operator interface configuration, the IMC-S/23x 
asks
Toggle to
YES
and press ENTER to configure the runtime display for
your application.
If you are not using DH-485 (see Configuring the IMC-S/23x in the 
Installation and Hookup section of this manual), the recommended 
setting of the runtime display configuration parameters for use with 
most serial devices is shown below:
TIP: If the Operator Interface display is double-spaced, turn off 
Linefeed Insertion. 
Setup Pasword?
Edit Runtime Display Configuration? NO
Runtime Display? YES
Runtime Display Serial Port? B
Display Refresh Time (SEC) = 0.50