Interpreting msg error codes – Rockwell Automation 1747-L55x,D174710.4 SLC 500 Ethernet User Manual

Page 36

Advertising
background image

4–6

Communicating on the Ethernet Network

Publication 1747-10.4

When the processor detects an error during the transfer of message
data, the processor sets the .ER bit and enters an error code that you
can monitor from your programming software.

Error Code

Description of Error Condition

02H

Target node is busy. The MSG instruction automatically reloads. If other messages are waiting, the message is
placed at the bottom of the stack.

03H

Target node cannot respond because message is too large.

04H

Target node cannot respond because it does not understand the command parameters OR the control block was
inadvertently modified.

05H

Local processor is offline (possible duplicate node situation).

06H

Target node cannot respond because requested function is not available.

07H

Target node does not respond.

08H

Target node cannot respond.

09H

Local modem connection was lost.

0AH

Buffer unavailable to receive SRD reply.

OBH

Target node does not accept this type of MSG instruction.

0CH

Received a master link reset (one possible source is from the DF1 master).

10H

Target node cannot respond because of incorrect command parameters or unsupported command.

11H

Local file has constant file protection.

12H

Local channel configuration protocol error exists.

13H

Local MSG configuration error in the Remote MSG parameters.

15H

Local channel configuration parameter error exists.

16H

Target or Local Bridge address is higher than the maximum node address.

17H

Local service is not supported.

18H

Broadcast (Node Address 255) is not supported.

19H

Improperly formatted Logical ASCII Address string. String not properly terminated with a NULL character, or the string
length does not match the value in the length parameter.

20H

PCCC Description: Host has a problem and will not communicate.

30H

PCCC Description: Remote station host is not there, disconnected, or shutdown.

37H

Message timed out in local processor.

38H

Message disabled pending link response.

40H

PCCC Description: Host could not complete function due to hardware fault.

50H

Target node is out of memory.

60H

Target node cannot respond because file is protected.

70H

PCCC Description: Processor is in Program Mode.

80H

PCCC Description: Compatibility mode file missing or communication zone problem.

90H

PCCC Description: Remote station cannot buffer command.

B0H

PCCC Description: Remote station problem due to download.

C0H

PCCC Description: Cannot execute command due to active IPBs.

D0H

No IP address configured for the network, –or–
Bad command – unsolicited message error, –or–
Bad address – unsolicited message error, –or–
No privilege – unsolicited message error

D1H

Maximum connections used – no connections available.

D2H

Invalid internet address or host name.

D3H

No such host / cannot communicate with the name server.

Interpreting MSG Error