Rockwell Automation 1771-VHSC , D17716.5.74 Very High S User Manual
Page 43

4–4
Configuring Your Module
Description
Bits
Word
Word 3
bits 00Ć02
Determine rate measurement mode, encoder mode, counter mode or
period/rate mode for COUNTER 0.
Mode
Bit
02
01
00
Counter mode
0
0
0
Encoder X1 mode
0
0
1
Encoder X4 mode
0
1
0
Counter not used
0
1
1
Period/rate mode
1
0
0
Rate Measurement mode
1
0
1
Continuous/rate mode
1
1
0
bit 03
Not used
bits 04Ć06
Determine store count mode for COUNTER 0.
Mode
Bit
06
05
04
Store count mode not used for counter 0
0
0
0
Mode 1 (store/continue) used
0
0
1
Mode 2 (store/wait/resume) used
0
1
0
Mode 3 (storeĆreset/wait/start) used
0
1
1
Mode 4 (storeĆreset/start) used
1
0
0
bit 07
Invert signal bit for gate/reset terminal.
0 = Not inverted
1 = Inverted
bits 08Ć10
Determine rate measurement mode, encoder mode, counter mode or
period/rate mode for COUNTER 1.
Mode
Bit
10
09
08
Counter mode
0
0
0
Encoder X1 mode
0
0
1
Encoder X4 mode
0
1
0
Counter not used
0
1
1
Period/rate mode
1
0
0
Rate Measurement mode
1
0
1
Continuous/rate mode
1
1
0
bit 11
Not used
bits 12Ć14
Determine store count mode for COUNTER 1.
Mode
Bit
14
13
12
Store count mode not used for counter 1
0
0
0
Mode 1 (store/continue) used
0
0
1
Mode 2 (store/wait/resume) used
0
1
0
Mode 3 (storeĆreset/wait/start) used
0
1
1
Mode 4 (storeĆreset/start) used
1
0
0