Configuring Your Module

Description

Bits

Word

Mode 4 (storeĆreset/start) used

1

0

0

bit 15

Invert signal bit for gate/reset terminal.

0 = Not inverted

1 = Inverted

Words 5

thru 12

Rollover value. When rollover value is reached, the counter value

becomes 000,000 and counting continues from that point. The range

for both MSD and LSD is 0 to 999.

Word 5

Rollover value. Most significant digit for counter 0.

Word 6

Rollover value. Least significant digit for counter 0.

Word 7

Rollover value. Most significant digit for counter 1.

Word 8

Rollover value. Least significant digit for counter 1.

Word 9

Rollover value. Most significant digit for counter 2.

Word 10

Rollover value. Least significant digit for counter 2.

Word 11

Rollover value. Most significant digit for counter 3.

Word 12

Rollover value. Least significant digit for counter 3.

Words 13

thru 20

Preset values. The preset value is loaded into the respective counter

when its preset bit is set. The preset count value overrides the current

count, and becomes the new count value in the counter. When a

preset value is loaded, the counter begins to count from that value.

Word 13

Preset value. Most significant digit for counter 0.

Word 14

Preset value. Least significant digit for counter 0.

Word 15

Preset value. Most significant digit for counter 1.

Word 16

Preset value. Least significant digit for counter 1.

Word 17

Preset value. Most significant digit for counter 2.

Word 18

Preset value. Least significant digit for counter 2.

Word 19

Preset value. Most significant digit for counter 3.

Word 20

Preset value. Least significant digit for counter 3.

Words 21

thru 24

The ranges of words 21 thru 24 depend on the mode selected in word

3, bits 00Ć02.

In encoder/counter mode or period/rate mode, these are scalar words,

and divide the incoming pulse train at the gate/reset terminal by a

predetermined integer (1, 2, 4, 8, 16, 32, 64 and 128). Default value

is 1.

In rate measurement mode, these are time base values. Range is in

milliseconds from 10ms to 2 seconds in 10ms intervals.

Word 25

bits 00Ć03

Allows you to tie the output to any of the 4 counters. Bits correspond

to the counters: bit 00 for counter 0, bit 01 for counter 1, bit 02 for

counter 2, and bit 03 for counter 3.

bits 04Ć15

Not used.

Word 26

Most significant digit of the ON value of output 0.

Word 27

Least significant digit of the ON value of output 0.

Word 28

Most significant digit of the OFF value of output 0.

Word 29

Least significant digit of the OFF value of output 0.

Words 30

thru 34

These words are a repeat of words 25 through 29 with the exception

of the output number. These words are for output 1.