5–4

Module Status and Input Data

Definition

Bit

Word

Words 12

Counter 0 Store count values LSD (range 0Ć999)

Words 13

Counter 1 Store count values MSD (range 0Ć999) in encoder/counter

mode; or frequency value MSD (range 0Ć500) in rate measurement or

period/rate mode

Words 14

Counter 1 Store count values LSD (range 0Ć999)

Words 15

Counter 2 Store count values MSD (range 0Ć999) in encoder/counter

mode; or frequency value MSD (range 0Ć500) in rate measurement or

period/rate mode

Words 16

Counter 2 Store count values LSD (range 0Ć999)

Words 17

Counter 3 Store count values MSD (range 0Ć999) in encoder/counter

mode; or frequency value MSD (range 0Ć500) in rate measurement or

period/rate mode

Words 18

Counter 3 Store count values LSD (range 0Ć999)

Word 19

Counter 0 Total counts occurring at gate/reset pin in period/rate or

continuous/rate modes (MSD range = 0Ć999)

Word 20

Counter 0 Total counts occurring at gate/reset pin in period/rate or

continuous/rate modes (LSD range = 0Ć999)

Word 21

Same as word 19, but for counter 1.

Word 22

Same as word 20, but for counter 1.

Word 23

Same as word 19, but for counter 2.

Word 24

Same as word 20, but for counter 2.

Word 25

Same as word 19, but for counter 3.

Word 26

Same as word 20, but for counter 3.

In this chapter you learned the meaning of the status information that
the module sends to the processor.