Period/Rate and Continuous/Rate Examples

E–6

Figure E.2

Operation of Outputs in Period/Rate and Continuous/Rate with Scaler = 2

50Hz at Gate/Reset

50% Duty Cycle

Scaler = 2

CHANNEL IN CONTINUOUS/RATE

ON at 20,000

OFF at 80,000

Scaler = 2

4MHz Count

= 80,000

4MHz Count

= 20,000

What the

counter sees

internally with

scaler = 2.

CHANNEL IN PERIOD/RATE

ON at 20,000

OFF at 80,000

Scaler = 2

4MHz Count = 80,000

Counter times

width of pulse

4MHz count = 80,000

Counter

Idle

12633-I

Figure E.3

Operation of Outputs in Period/Rate and Continuous/Rate with Scaler = 4

50Hz at Gate/Reset

50% Duty Cycle

Scaler = 4

CHANNEL IN CONTINUOUS/RATE

ON at 20,000

OFF at 80,000

Scaler = 4

4MHz Count

= 80,000

4MHz Count

= 20,000

What the

counter sees

internally with

scaler = 4.

CHANNEL IN PERIOD/RATE

ON at 20,000

OFF at 80,000

Scaler = 4

4MHz Count = 160,000

Counter times

width of pulse

4MHz count = 160,000

Counter

Idle

4MHz Count = 160,000

4MHz Count

= 80,000

4MHz Count

= 20,000

4MHz Count

= 20,000

12634-I