10-8 Troubleshoot the Card

Publication 1784-IN029C-EN-P - June 2001

Change Memory and Interrupt Resources

If you experience difficulty in configuring the PCD card, you should change the

memory and interrupt resources.

To find the available resources in your system,

Select Start

Programs

Administrative Tools

Windows NT Diagnostics. If

no interrupts are available, you may need to disable another device.

If You Are using:

Change Resources by:

pure NT (no third-party plug-and-play
software)

using the PCD card configuration tool on the
Windows Control Panel

SystemSoft’s CardWizard third-party
plug-and-play software

using the PCD card configuration tool on the
Windows Control Panel

Unicore/Touchstone Software’s CardWare
third-party plug-and-play software

contacting Rockwell Automation Technical
Support for assistance

Phoenix/Softex’s Card Executive
third-party plug-and-play software

contacting Rockwell Automation Technical
Support for assistance

IMPORTANT

Windows NT diagnostics may not show all interrupts that are
in use. If you continue to have problems, try another IRQ.
Recommended IRQ values are 7, 9, 10, 11, 12, and 15.

IMPORTANT

After you change these resources, you must reboot your PC for
the changes to take effect.