Summary of changes, New information updated information – Rockwell Automation 1794-ID2 U.MNL INCREMENTAL ENCODER User Manual

Page 3

Advertising
background image

Summary of Changes

Publication 1794-UM015B-EN-P - May

2001

Summary of Changes

The information contained in this manual pertains to the series B
version of the 1794-ID2 frequency input module.

This version of this publication contains information on control word
2, for setting the filter function for the counters. This filter
information is contained in chapter 1 and identified in chapters 4
and 5.

The vibration specifications for this module have been updated. The
specification is as follows:

Environmental Conditions

Operational Temperature

Storage Temperature

Relative Humidity

Shock Operating

Nonoperating

Vibration

0 to 55

o

C (32 to 131

o

F) Note: Do not connect

maximum input voltage simultaneously to all

inputs if the module ambient temperature is

expected to exceed 40

o

C.

-40 to 85

o

C (-40 to 185

o

F)

5 to 90% noncondensing (operating)

5 to 80% noncondensing (nonoperating)

30g peak acceleration, 11(+1)ms pulse width

50g peak acceleration, 11(+1)ms pulse width

Tested 50g @ 10-500Hz per IEC 68Ć2Ć6

New Information

Updated Information

Advertising