Rockwell Automation 1794-ID2 U.MNL INCREMENTAL ENCODER User Manual

Page 57

Advertising
background image

5–5

How Communication Takes Place and I/O Image Table Mapping with the DeviceNet Adapter

Publication 1794ĆUM015B-EN-P - May 2001

Bit/Word Definitions

for the incremental encoder Module (1794-ID2)

Word

Bit

Definition

Read

Word 1

Bit 00

Status for input A (pulse transmitter 0) - This bit, when set, indicates a signal at A.

Word 1

Bit 01

Status for input B (pulse transmitter 0) - This bit, when set, indicates a signal at B.

Bit 02

Status for input Z (pulse transmitter 0) - This bit, when set, indicates a signal at Z.

Bit 03

Status for input G (pulse transmitter 0) -This bit, when set, indicates a signal at G.

Bit 04

Status for input A (pulse transmitter 1) - This bit, when set, indicates a signal at A.

Bit 05

Status for input B (pulse transmitter 1) - This bit, when set, indicates a signal at B.

Bit 06

Status for input Z (pulse transmitter 1) - This bit, when set, indicates a signal at Z.

Bit 07

Status for input G (pulse transmitter 1) - This bit, when set, indicates a signal at G.

Bit 08 (10)

Cal 0 - This bit, when set (1), indicates that counter 0 has been calibrated. This bit is reset by CalReset.

Bit 09 (11)

Cal 1 - This bit, when set (1), indicates that counter 1 has been calibrated. This bit is reset by CalReset.

Bit 10 (12)

Store 0 - This bit, when set (1), indicates a counter value is saved in store 0. This bit is reset by StoreReset.

Bit 11 (13)

Store 1 - This bit, when set (1), indicates a counter value is saved in store 1. This bit is reset by StoreReset.

Bit 12 (14)

Preset Reached 0 (PR0) - When this bit is set (1), in all configuration modes, the counter 0 value equals the

preset 0 value, either in a positive or negative direction. This bit is reset by PresetReset0 and can only be set

again after at least 1 more pulse.

Bit 13 (15)

Preset Reached 1 (PR1) - When this bit is set (1), in all configuration modes, the counter 1 value equals the

preset 1 value, either in a positive or negative direction. This bit is reset by PresetReset1 and can only be set

again after at least 1 more pulse.

Bit 14-15

(16-17)

Not used - set to 0

Read

Word 2

Bits 00-15

(00-17)

Store 0 - Saved counter value on channel 0

Read

Word 3

Bits 00-15

(00-17)

Store 1 - Saved counter value on channel 1

Read

Word 4

Bits 00-15

(00-17)

Channel 0 Current Counter Value- Current value in counter 0

Read

Word 5

Bits 00-15

(00-17)

Channel 1 Current Counter Value- Current value in counter 1

Read

Word 6

Bits 00-15

(00-17)

Counter 0 Readback - Counter word readback - last value written to write word 1

Read

Word 7

Bits 00-15

(00-17)

Counter 1 Readback - Counter word readback - last value written to write word 2

Read

Word 8

Bits 00-15

(00-17)

Revision Read - identification of latest software version code

Advertising