Rockwell Automation 1794-ID2 U.MNL INCREMENTAL ENCODER User Manual

Page 71

Advertising
background image

6–9

Input, Output and Configuration Files for Analog Modules when used with ControlNet

Publication 1794ĆUM015B-EN-P - May 2001

Definition

Bit

Output

Word

Word 1

Channel 1 Control Word - Control word for setting the function of counter 1.

Bits 00-02

02

01 00

Mode Selection bits

0

0

0

Counting on positive (rising) edge of input signal A. (Up/dwn counting determined by B.)

0

0

1

Quadrature encoder X1

0

1

0

Quadrature encoder X2

0

1

1

Quadrature encoder X4

1

0

0

Counting up on the positive edge of input signal A, and down on positive edge of input signal B.

1

0

1

No count function.

1

1

0

No count function.

1

1

1

No count function.

Bit 03

Preset bit - A positive edge on this bit moves the value in Preset X to Counter X, independent of Preset Enable.

Bit 04

Preset Enable bit - When this bit is set (1), a positive edge on Z preloads Counter X = Preset X, independent of

Cal Enable.

Bit 05

Count Enable bit - When this is set (1), the pulse counter is counting.

Bits 06-08

(06 10)

Calibration Control bits - bits 06, 07 and 08

(06-10)

06 Enable bit - When this bit is set (1), the counter can be calibrated.
07 Direction bit - When this bit set (1), calibration is performed in a negative direction; when reset (0),

calibration is performed in a positive direction.

08 Reset bit - Calibration is acknowledged and a new calibration is enabled on a positive edge on this bit.

Bits 09-10

10

09 Gate Control bits

0

0

No gate function on input G

0

1

Counting only if G is high (active)

1

0

Counting only if G is low (inactive)

1

1

Calibration if G is high (active) and ???

Bits 11-12

(13-14)

12

11 Store Control bits - These bits will trigger a Store only if the channel Store status bit (L0 or L1) is

cleared (0).

0

0

Save the counter value on the positive edge of Z (if Store X = 0)

0

1

Save the counter value on the positive edge of G (if Store X = 0)

1

0

Save the counter value on the negative edge of G (if Store X = 0)

1

1

Save the counter value on the positive edge and negative edge of G (if Store X = 0)

Bit 13

Rollover bit - When set (1), the counter counts up to the preset and then restarts at 0. If this bit is reset (0) (not

rollover), the rollover preset value = FFFF (hex = 65535 (decimal).

Bit 14

Store Reset bit - A positive edge on this bit resets Store X in Signals.

Bit 15

Store Reset bit - A positive edge on this bit resets Preset Detected in Signals.

Word 2

Bits 00-15

Preset 0 - Value to load or compare with counter 0

Word 3

Bits 00-15

Preset 1 - Value to load or compare with counter 1