Publication 1747-UM002A-US-P - June 2000

6-42 Library of Routines

The shared memory segment address must be set to an address that
does not conflict with other hardware and software. The
recommended segment address is 0xC800. You can use any of the
following shared segment addresses (listed in hex):

C000 - D000

C200 - D200

C400 - D400

C600 - D600

C800 - D800

CA00 - DA00

CC00 - DC00

CE00 - DE00

irqnum defines the ISA-bus interrupt number assigned to the scanner.
irqnum must be set to one of the values listed in the table below or
the scanner cannot be opened. The MS-DOS API library
communicates with the scanner via interrupts and installs an interrupt
service routine for the interrupt. The application must not service
these interrupts.

The IRQ assignment must be set to an interrupt that does not conflict
with other hardware and software. The recommended interrupt
assignment is IRQ11.

Return Value:

irqnum:

IRQ assignment:

10

IRQ10

11

IRQ11

12

IRQ12

14

IRQ14

15

IRQ15

Name:

Value:

Description:

SUCCESS

0

scanner was opened successfully

ERR_OCOPEN

1

scanner is already open

ERR_OCPARAM

2

invalid value in segaddr or irqnum

ERR_OCMEM

3

shared memory not found

Advertising