Rockwell Automation 1747-PCIS API Software - Open Controller User Manual

Page 42

Advertising
background image

Publication 1747-UM002A-US-P - June 2000

3-10 Developing Applications

/*
** Read first Input word
*/
retcode = OC_ReadInputImage( Handle, NULL, input_slot, 0, 1, &wData );
if ( retcode != SUCCESS )
{

printf( ”\nERROR: OC_ReadInputImage failed: %d\n”, retcode );
Ioexit( 1 );

}
printf( ”\n\n First input image data word --> 0x%04x \n”, wData );
delay( 3000 );
/*
** Write to the first Output word
*/

printf( ”\n\n Incrementing first discrete output word. \n” );
for ( wData=0; wData < 256; wData++)
{

retcode = OC_WriteOutputImage( Handle, NULL, output_slot, 0, 1,

&wData );

if ( retcode != SUCCESS )
{

printf(”\nERROR: OC_WriteOutputImage failed: %d\n”,

retcode);

Ioexit(1);

}
delay ( 10 );

}
/*
** Must always close the scanner before exiting
*/
OC_CloseScanner( Handle );
printf( ”\n\n Program is done! \n\n” );

}

/* end main() */

/************************************************************************
*
*

Name: Ioexit

*
*

Description:

*
*

Common error handling routine. This routine displays any

*

extended error and exits the program.

*
*

Arguments:

*

retcode : int ( input )

*

This error code is passed to the exit() routine.

*
*

External effects:

*

The program is terminated.

*
*

Return value:

*

none

*
************************************************************************/
void Ioexit( int retcode )
{

OCEXTERR exterr;
char *msg;
if (OC_GetExtendedError(Handle, &exterr) == SUCCESS)
{

if ( exterr.ErrorCode != 0 )
{

Scan I/O

Advertising
This manual is related to the following products: