Oc_gettemperature, Oc_gettemperature -35 – Rockwell Automation 1747-PCIS API Software - Open Controller User Manual
Page 95

Publication 1747-UM002A-US-P - June 2000
Library of Routines 6-35
Return Value:
Considerations:
Supported in the DOS API library and the Windows NT API library
Example:
HANDLE
Handle;
BYTE
sw_pos;
int
retcode;
retcode = OC_GetSwitchPosition( Handle, &sw_pos );
if ( sw_pos == SWITCH_BOTTOM )
OC_SetScanMode ( Handle, SCAN_IDLE );
OC_GetTemperature
OC_GetTemperature reads the current temperature of the 1746 I/O
PCI Interface’s built-in thermometer.
Syntax:
int
OC_GetTemperature(HANDLE handle, BYTE*temp);
Parameters:
Description:
The temperature is updated every 10 seconds by the scanner.
The optimal operating temperature range for the 1746 I/O PCI
Interface is 0° to 60°C. When OC_GetTemperature returns a value of
75_ C or higher, the 1746 I/O PCI Interface is operating beyond its
optimal operating temperature range and you need to correct the
situation.
The scanner must be initialized before you can monitor the
temperature.
Name:
Value:
Description:
SUCCESS
0
switch position was read successfully
ERR_OCACCESS
2
handle
does not have access to scanner
ERR_OCINIT
5
scanner has not been initialized, see OC_InitScanner
Parameter:
Description:
handle
Must be a valid handle returned from OC_OpenScanner
temp
Returns the temperature in degrees Celsius