Oc_demandoutputscan, Oc_demandoutputscan -8 – Rockwell Automation 1747-PCIS API Software - Open Controller User Manual

Page 68

Advertising
background image

Publication 1747-UM002A-US-P - June 2000

6-8 Library of Routines

The scanner updates the input image with data read from the
modules. Use OC_ReadInputImage to read data from the input image.

Return Value:

Considerations:

Supported in the DOS API library and the Windows NT API library

Example:

HANDLE

Handle;

int

retcode;

retcode = OC_DemandInputScan( Handle, OCWAIT );

OC_DemandOutputScan

OC_DemandOutputScan forces the scanner to immediately perform
an output scan.

Syntax:

int

OC_DemandOutputScan(HANDLE handle, int mode);

Parameters:

Description:

The scanner updates module outputs from the data in the output
image. Use OC_WriteOutputImage to write data to the output image.

Name:

Value:

Description:

SUCCESS

0

demand input request was successful

ERR_OCACCESS

2

handle

does not have access to scanner

ERR_OCRESPONSE

10

scanner did not respond to request

ERR_OCSCANCFG

14

scanner has not been configured

Parameter:

Description:

handle

Must be a valid handle returned from OC_OpenScanner

mode

If

mode

is:

OCWAIT

OC_DemandOutputScan waits for the output scan to
be completed before returning to the caller.

OCNOWAIT OC_DemandOutputScan returns immediately.

Advertising