Oc_errormsg, Oc_errormsg -14 – Rockwell Automation 1747-PCIS API Software - Open Controller User Manual

Page 74

Advertising
background image

Publication 1747-UM002A-US-P - June 2000

6-14 Library of Routines

Description:

This function enables or disables the scanner from scanning the
module in a specific

slotnum

. This applies to both the input and

output scan. Slots that are disabled are not included in the I/O scan.
By default, all slots are enabled.

Return Value:

Considerations:

Supported in the DOS API library and the Windows NT API library

Example:

HANDLE

Handle;

int

retcode;

retcode = OC_EnableSlot( Handle, 6, SLOT_DISABLE ); /*

Exclude slot 6 */

OC_ErrorMsg

OC_ErrorMsg returns a descriptive text message associated with the
API return value

errcode

.

Syntax:

int OC_ErrorMsg(int errcode, char **msg);

Description:

The null-terminated message string is placed in a static buffer that is
reused each time this function is called. A pointer to this buffer is
returned in

msg

.

Name:

Value:

Description:

SUCCESS

0

module was updated successfully

ERR_OCACCESS

2

handle

does not have access to scanner

ERR_OCNOFORCES

15

no forces installed, scanner cannot enable forces

ERR_OCPARAM

8

parameter contains invalid value

ERR_OCRESPONSE

10

scanner did not respond to request

ERR_OCSCANCFG

14

scanner has not been configured

Advertising