Publication 1747-UM002A-US-P - June 2000

5-2 Configuring I/O Modules

SlotCfg

contains information about each slot in the racks. The 1746

I/O PCI Interface supports as many as 31 slots, numbered 0 to 30. Slot
0 is the adapter slot (left slot of rack 1) and is invalid for scanner
functions. Each slot is described by the structure

OCSLOTCFG

:

struct {

BYTE

mix;

/* Module I/O Mix value */

BYTE

type;

/* Module Type */

BYTE

InputSize;

/* number of inputs in bytes */

BYTE

OutputSize;

/* number of outputs in bytes */

WORD

M0Size;

/* size of M0 file in words */

WORD

M1Size;

/* size of M1 file in words */

WORD

GSize;

/* size of G file in words */

WORD

*GData;

/* pointer to array of length GSize

words */

char

*Name;

/* pointer to module name string */

} OCSLOTCFG;

You can specify a module by name or by mix and type. You only
specify G data if the module uses G files (such as the 1747-SN). If the

Name

pointer is NULL, OC_CreateIOConfiguration uses

mix

and

type

to identify the module. See page 4 for the

mix

and

type

values.

OC_CreateIOConfiguration supplies the

InputSize

,

OutputSize

,

M0Size

,

M1Size

,

Gsize

, and

Name

fields.

If

Name

points to a string containing a valid module name, the module

name identifies the module. OC_CreateIOConfiguration supplies the

mix

,

type

,

InputSize

,

OutputSize

,

M0Size

,

M1Size

, and

Gsize

fields.

Initialize empty slots and slot 0 with a

mix

value of 0xFF and a

type

value of 0xFF.

If the module is not in the internal database,
OC_CreateIOConfiguration doesn’t alter the OCSLOTCFG.

To support modules not included in the internal database of modules,
the host application can initialize the

mix

,

type

,

InputSize

,

OutputSize

,

M0Size

,

M1Size

, and

GSize

before downloading the

I/O configuration to the scanner. See the I/O module’s user manual to
determine the proper configuration information.

After the OC_CreateIOConfiguration and OCGetIOConfiguration
functions return, the I/O configuration structure must be checked for
installed modules with G files. If the

Gsize

field of a non-empty slot

configuration is not zero, then the module contains a G file. If the
module contains a G file, initialize

GData

to point to an array of

Gsize

words to be loaded into the module during scanner

configuration. See the I/O module’s user manual to determine the
proper G file data.