Publication AG-UM008C-EN-P - February 2005

3-2 Configuring MicroLogix 1100/1200/1500 Controllers

Overview

To configure a MicroLogix 1100/1200/1500 controller:

1. Install the controller; connect the serial cable to one of the

communication channels.

2. Define the processor’s communication characteristics using

RSLogix

™

500 programming software.

3. Install and configure the modem for communication with the

controller; connect the modem to one of the controller’s serial
channels.

Figure 3.1 Configuring a MicroLogix 1100/1200/1500 Controller

Installing the Controller

For details about installing the controller, see the MicroLogix 1100
Installation Instructions, publication 1763-IN001, MicroLogix 1200
Installation Instructions, publication 1762-IN006 or the MicroLogix
1500 Installation Instructions, publication 1764-IN001. Cable pinouts
are shown in each example configuration as well as in Appendix A.

RSLogix 500 Programming Software

Modem

Modem

MicroLogix 1500

IMPORTANT

The MicroLogix 1200/1500 channel 0 port is not
optically isolated. For all modem applications, an
external optical isolator is recommended. You may
either supply your own or use a 1761-NET-AIC. The
MicroLogix 1500 Channel 1 port and MicroLogix
Channel 0 port are optically isolated.