Panel cutout dimensions, Mounting the monitor in panel – Rockwell Automation 6186-Mxxx Industrial Monitors User Manual User Manual

Page 16

Advertising
background image

16

Publication 6186M-UM001J-EN-P - July 2008

Chapter 2 Installing the Monitor

Supporting panels must be at least 14 gauge to be sure of proper
sealing against water and dust and to provide proper support.
The mounting hardware supplied accommodates panels up to
6.00 mm (0.236 in.) thick.

Panel Cutout Dimensions

The Cutout Dimensions table lists the panel cutout dimensions for
each monitor. Use the full-size template shipped with each monitor to
mark the cutout dimensions.

Mounting the Monitor in Panel

Follow these directions to mount the monitor in a panel.

1. Cut the panel opening using the appropriate cutout dimensions.

2. Attach the cables to the monitor if access to the rear of the

monitor will not be possible after the installation.

3. Verify that the sealing gasket is properly positioned on the

monitor.

This gasket forms a compression-type seal. Do not use sealing
compounds.

4. Place the monitor in the panel cutout.

ATTENTION

Failure to follow these guidelines may result in personal injury
or damage to the panel components.

Monitor Model

Cutout Dimensions, Approx. (H x W)

1200M

238.0 x 318.0 mm (9.37 x 12.51 in.)

1500M

285.6 x 386.6 mm (11.24 x 15.22 in.)

1700M

329.5 x 424.0 mm (12.97 x 16.69 in.)

1900M

363.5 x 449.6 mm (14.31 x 17.70 in.)

Advertising