Mounting the Monitor in a Rack

Follow these directions to mount the monitor in a rack.

1. Place the 1200M, 1500M, or 1700M monitor in the rack adapter

and attach it to the rack adapter with the screws provided.

2. Secure the monitor or adapter to the cabinet by installing screws

through the holes in the monitor or adapter, and into the
mounting rails behind.

IMPORTANT

The mounting rails that run vertically along the inside edges of
the front opening of an EIA-rack cabinet can be of two types.

Wide rails have holes spaced 12.7 mm (0.5 in.) and 31.8 mm (1.25
in.) on centers, in a repeating pattern. Wide rails are prevalent in
Europe.

Universal rails have holes spaced 12.7 mm (0.5 in.), 15.9 mm
(0.625 in.), and 31.8 mm (1.25 in.) on centers, in a repeating pattern.
The universal rails have a hole pattern that contains the wide
pattern but provides an additional hole at the midpoint of the
pattern. Universal rails are most prevalent in the United States.

Rack Adapter

Advertising