Rockwell Automation 6186-Mxxx Industrial Monitors User Manual User Manual
Page 50

50
Publication 6186M-UM001J-EN-P - July 2008
Appendix A Specifications
Video
OSD
Controls
Operator Input
Electrical
Attribute
Value
Video bandwidth
1200M
1500M
1700M/1900M
50 MHz (max. video dot clock)
80 MHz (max. video dot clock)
135 MHz (max. video dot clock)
Video input signal
RGB analog
(white level = 0.700V above ref. Black, into
75 Ohms, DVI single ended)
Sync input signals
Separate horizontal and vertical sync
control, TTL signal levels
Video input connection
1200M/1500M/1700M/1900M
Female HD-15 or DVI (5-BNC connector
support through cable adapter)
Attribute
Value
OSD controls and indicators
Automatic Screen Setup, Brightness,
Contrast, Sharpness, Manual Color
Adjustment, Horizontal/Vertical Position,
OSD Lock & Unlock, OSD Time Out timer,
Factory Reset, Display Resolution
Information, Power On/Off, and Sync
Detected
Attribute
Value
Touch screen description
1200M/1900M
1500M/1700M
Resistive antiglare
Resistive or capacitive antiglare
Attribute
Value
Inputvoltage, ac
90…264V ac, autoswitching
Line frequency
47…63 Hz
Power consumption, ac
1200M
1500M
1700M/1900M
13.5 W
18 W
36 W
Input voltage, dc
1200M/1500M/1700M/1900M
9…36V dc