Running the Demo Unit

4-3

The drive is now programmed with a basic configuration that
uses external I/O control.

Step 11. Turn the

CONF

IN

switch to 1.

Step 12. Turn the

STOP

/

RUN

switch to

RUN

. Notice that the

drive starts and the

RUN

LED

turns on.

Step 13. Turn the

ANALOG

CHAN

#1 switch (the main speed

reference) fully clockwise to run the drive at
maximum speed (60 Hz).

Step 14. Turn the

ANALOG

CHAN

#1 switch fully

counter-clockwise to run the drive at minimum
speed (5 Hz).

Step 15. Turn the

STOP

/

RUN

switch to

STOP

to stop the drive.

Step 16. Change the value of parameter P-10 to 1 (Keypad

Control).

Step 17. Turn the

STOP

/

RUN

switch to

RUN

. Note that the drive

does not start because the start control is now the
keypad. Also notice that the

RUN

LED

does not turn

on.

Step 18. Turn the

STOP

/

RUN

switch to

STOP

.

Step 19. Press

.

Notice that the drive starts and the

RUN

LED

turns on.

Step 20. Press

to stop the drive.

Step 21. Change the value of parameter P-10 back to 2.

Table 4.1 – Parameter Values for Basic Configuration

No.

Parameter Name

Value

P-00

MINIMUM

SPEED

5 Hz

P-01

MAXIMUM

SPEED

60 Hz

P-02

MOTOR

OVERLOAD

CURRENT

0.4 A

P-03

REVERSE

DISABLE

0

P-05

CURRENT

LIMIT

150%

P-10

START

CONTROL

2 (2-Wire Start)

P-20

MAIN

SPEED

REFERENCE

0 (Analog Input 1)

P-30

ACCELERATION

TIME

1

3.0 sec

P-31

DECELERATION

TIME

1

3.0 sec

P-34

STOP

CONTROL

0 (Ramp-to-Rest)

P-50

BASE

VOLTAGE

100 V

P-51

BASE

SPEED

60 Hz