Running the Demo Unit

4-4

Lab 2: Using the display parameters to view drive
status.

Tools required: None

Step 1. Press

until the

PROGRAM

LED

turns off to enter

display mode.

Step 2. Press

once. The letter "d" will be displayed

along with a two-digit number.

Step 3. Continue to depress

(multiple times) to cycle

through all the display parameters.

Note: When you stop or pause at a display parameter for
more than 2 seconds, the value of that parameter is
displayed.

Step 4. Press

until parameter d-01 [

OUTPUT

FREQUENCY

]

is displayed.

Step 5. Turn the

CONF

IN

switch to 1.

Step 6. Turn the

STOP

/

RUN

switch to

RUN

.

Step 7. Turn the

ANALOG

CHAN

#1 switch fully clockwise to

run the drive at maximum speed. The display
should read at or near 60.0 Hz.

Step 8. Turn the

ANALOG

CHAN

#1 switch fully

counter-clockwise to run the drive at minimum
speed. The display should read 5.0 Hz.

Step 9. Press

until parameter d-00 [

COMMAND

FREQUENCY

] is displayed. The display should read

5.0 Hz, which is the value of the main speed
reference,

ANALOG

CHAN

#1.

Step 10. Turn the

STOP

/

RUN

switch to

STOP

to stop the drive.

Lab 3: Using configured inputs and outputs.

Tools required: None

A configured input is an input that can be programmed to
perform various functions. On the demo unit, the

CONF

IN

switch is wired as the configured input to terminals 2 and 6
on the drive’s terminal strip.