Programming basics, Parameter menu structure, Parameter types – Rockwell Automation SP120 AC Drive Demo Unit User Manual
Page 9: Hapter

Programming Basics
3-1
C
HAPTER
3
Programming Basics
To program the drive for a specific application, you display
the appropriate parameter and adjust it as required. The
parameters are used to define characteristics of the drive.
3.1
Parameter Menu Structure
The SP200 drive has two kinds of parameters: program
parameters (P-xx), which configure the drive operation, and
display parameters (d-xx), which display information
regarding the drive status.
3.2
Parameter Types
There are three types of parameters:
• Tunable parameters can be adjusted or changed while the
drive is running or stopped.
• Configurable parameters can be adjusted or changed
only while the drive is stopped.
• Read-only parameters cannot be adjusted.
Table 3.1 – Parameter Organization
Range
Parameter Group
Parameter Type
P-00 to P-05
P-10 to P-13
P-20 to P-29
P-30 to P-38
P-40 to P-48
P-50 to P-55
P-60 to P-64
Protection
Digital Input/Output
Speed Reference
Dynamic Control
Fixed Speeds
V/Hz Curve
Utility
Program Parameters
d-00 to d-09
Display Parameters
Display Parameters