Velocity
Performs a standard acceleration to velocity vibration measurement.
These are the settings for the measurement parameters.
Table 36 - Types of Offroute Measurements
Type
Description
Parameter
Value
Display Format
Spectrum
Units
A -> V
High-pass frequency
1.1 Hz
Input Channel
X
Fmax 1
kHz
Lines/Samples
400 Lines
Averages
4
Overlap
50%
Type
Spectral
Ext. Trigger Slope
Positive
Trigger Level
2 V
Bin Zeroing
On