Why does the magnitude reading not correspond to the calculated
overall value?
Emonitor can calculate an overall value from a spectrum measurement. Under
some conditions, this value may not be the same as the magnitude measurement
for the same location. The common use for this are:
•
The measurement filter is not the same for the magnitude and the
spectrum measurement definitions. In this case the two measurement
definitions are measuring different frequency ranges.
•
The magnitude readings taken by the Enpac 2500 are broadband readings
and are not based on the spectrum data.