Rockwell Automation 1441-PEN25-Z Enpac 2500 Data Collector User Manual
Page 91
Advertising

Rockwell Automation Publication GMSI10-UM002D-EN-E - August 2012
91
Setting Up Measurements
Chapter 2
The following table shows the
collection specification
.
The following table shows the
transducer specification in the collection
specification.
Table 27 - Collection Specification for Time Waveform Measurement Definition
Transducer
Window
Signal Detection
Fmax
Lines
Phase
Order Norm?
Averages
Accelerometer
Hanning
Peak
2 kHz
400
No
No
1 linear
Table 28 - Transducer Specification in Time Waveform Collection Specification
Name
Base Unit
Input Type
Units
Calibration Value
DC Offset
Accelerometer
Acceleration
ICP Accel
g
100
0