Chapter 1 Prepare the PowerFlex 40 Drive Hardware
What You Need
This table lists the products you need to complete the tasks described in this chapter.
Follow These Steps
Quantity
Cat. No.
Description
1
22B-V2P3N104
PowerFlex 40 AC drive
1
22-COMM-D
DeviceNet adapter for use with the PowerFlex 40 drive
1
1485K-P1F5-R5
KwikLink right-angle micro male to micro female connector cable
1
1799-DNC5MMS
5-pin linear to micro male adapter
1
1485P-P1E4-R5
KwikLink sealed micro connector
V/T2
T/L3
S/L2
R/L1
U/T1
W/T3
BR+ BR-
DC- DC+
2
1
8
3
4
5
6
7
NODE
UP = OPEN = 1
2
1
3
4
5
6