Rockwell Automation EK-44750C Enwatch Unit User Manual

Page 18

Advertising
background image

Rockwell Automation Publication GMSI10-IN001A-EN-P - May 2013

18 Enwatch Unit

Sample length

Multiple of 256 bytes, maximum sample 32768 bytes if no trigger, 16384 bytes with pre-trigger (not used in first version of
Enwatch)

Filter settling time

HP 0.36 Hz

18 seconds

HP 2.67 Hz

3 seconds

HP 5.3 Hz

1.2 seconds

HP 23.8 Hz

0.3 seconds

Integrator HP 0.36 Hz

25 seconds

Integrator HP 2.67 Hz

8 seconds

Integrator HP 5.3 Hz

1.5 seconds

Integrator HP 23.8 Hz

0.8 seconds

gSE 200 Hz

88 milliseconds

gSE 5 kHz

2 milliseconds

Core

0.7 seconds

Time constant of 0.03 seconds

300 milliseconds

Time constant of 0.006 seconds

60 milliseconds

Time constant of 0.0012 seconds

12 milliseconds

Time constant of 0.00024 seconds

3 milliseconds

Trigger delay

0-32768 samples. The Emonitor software always uses 0.

Trigger channel

1-4 channels, TTL input 5-20 V
Maximum combined trigger current (channels 1-4), not to exceed 100mA.

Gain control

X1, X10, X100, X1000, X5, X50, X500, X5000
Download X1 always. The Enwatch unit autoranges and returns back the current gain for rescaling.

Anti-Alias filter

20 kHz, 2 kHz, 500 Hz, 100 Hz. This is read only. The Enwatch unit selects the proper filter.

gSE time constant

0.03, 0.006, 0.0012, 0.00024 seconds, the default is 0.03 seconds
if FMAX > 350Hz set to 0.00024 seconds
else if FMAX > 150 Hz set to 0.0012 seconds
else if FMAX > 37.5 Hz set to 0.006 seconds

If the measurement is overall only (no spectrum) then set to 0.03 seconds.

Integrator

One level of hardware integration

The hardware has a gain factor of:

2.67/f for the 0.36 Hz and the 2.67 Hz filter ranges (INTHI = 0)
38.9/f for the 5.3 Hz and 23.7 Hz filter ranges (INTHI = 1)

To convert from g->ips:
Velocity (ips peak) = [integrator output (volts peak)] x [1 / (gain factor)] x [accel scale factor

(g peak / mv peak)] x [61.24 / frequency]

Sample sequence allowed

4096 - one sample sequence uses one configuration table

Configuration tables

128 - one measurement point uses one table so the total is 128 points

Storage overhead

18 bytes per allocation

Flash memory lifetime

100,000 writes

Total available memory

640 Kilobytes

HOST software support (Emonitor)

Window types: Hanning, Hamming, Rectangular, Kaiser Bessel, Flattop

Number of lines

100, 200, 400, 800, 1600, 3200

Number of averages

1-99

Table 2 - Enwatch measurement capabilities

Product Feature

Capability

Advertising