22 Enwatch Unit
4. Select Setup>Calibration to select “Bias Voltage” as the input type for
this transducer. Set the calibration to 1000 and the offset to 0.
5. Click OK.
6. Select Setup>Collection to define a new collection specification. Select
“Transducer Check” as the transducer.
7. In the Emonitor software, define a numeric measurement definition with
V DC units and the “Transducer Bias” collection specification.
Magnitude And Phase Reading
A magnitude/phase reading is similar to any other data collector in the Emonitor
software. Use the “Mag & Phase” collection specification to set up an overall
measurement. Then select “1st Order” as the measurement filter (or any other
desired order).