Install and Wire the Drive

2-17

15

14

13

12

11

10

9

8

7

6

5

4

3

2

1

Customer

Interlock

Fault/Alarm Reset

+ 24 V

Slack Take-up

Motor

Thermostat

+ 24 V

24 V COM

Coast/Stop

+ 24 V

+ 24 V

Section Off

Jog Fwd

Jog Rev

Underwind Enable

24 Analog Out1

27

28

29

30

31

32

Fault

Analog Tachometer

Running

Alarm

18

17

16

5k

Analog Manual Reference

- COM

+ 10 V (Isolated)

+ Diameter Taper Range
or Trim Reference

21

23

19

20

22

+/-

Auto Reference

HI Range

LO Range

Common

COM

K10

Section Run

Under

Over

26 Analog Out2

25 Analog Out Com

3

2

1

Start/Stop by
User Contact

Reference Polarity Over/Under

Tachometer Voltage Polarity

Positive

Over

Positive

DC tachometer voltage polarity should be
based on the polarity of the reference and
the selection of the Over/Under switch.

Positive

Under

Negative

Negative

Over

Negative

Negative

Under

Positive

Figure 2.8b - Sample Regulator Board Terminal Strip Connection Diagram