Rockwell Automation WebPak 3000  DC Drives Hardware Reference, Installation and Troubleshooting User Manual

Page 45

Advertising
background image

Troubleshooting/Diagnostics

4-3

4.6

Fault and Alarm Messages, Descriptions and Code Numbers

Table 4.1 lists all possible OIM error messages generated by the drive and fault/alarm codes.

The error messages appear on the OIM display when certain drive conditions exist. Table 4-1 lists fault

codes and Table 4-2 lists alarm codes. Tables 4.1 and 4.2 list fault and alarm codes by number (Fxxxxx

= Fault; Axxxxx = Alarm), associated message visible at the OIM display and a description along with

possible causes.

Table 4.1 - Fault Codes

CODE

DISPLAY

DESCRIPTION

F00001 IET

(OVERCURRENT)

Armature current instantaneously exceeded 180% of

MAXIMUM

CURRENT

.

Possible causes:

Incorrect armature current feedback scaling

(MOTOR RATED ARM

AMPS, MAXIMUM CURRENT, CT TURNS RATIO

or J18 not set

properly).

One or more thyristors not operating.

Improper Current Minor Loop tuning.

Motor armature winding damaged.

F00002 TACHOMETER

LOSS

Tachometer or encoder feedback signal missing.
Possible causes:

Tachometer or encoder coupling failure.

Disconnected, loosely connected, or damaged tachometer or

encoder wires.

Pulse encoder supply voltage low.

Incorrect analog tachometer scaling.

Incorrect pulse encoder configuration.

Motor armature winding not connected or open circuit.

Blown inverting fault (DC) fuse.

Inverting fault breaker tripped.

Tachometer or encoder failure.

High inertia loads and high inductance armature circuits. To reduce

nuisance faults, increase the firing angle threshold (see section 4.7)..

F00003 OVERSPEED

Motor speed exceeded the 110% of

GEAR IN SPEED

.

Possible causes:

Incorrect tachometer or encoder scaling.

Blown field supply fuse(s).

Improper speed loop tuning.

Incorrect pulse encoder wiring.

F00004 FIELD CURRENT

LOSS

Field Current Regulator kit field supply:

FIELD FEEDBACK

(P.589) fell

below the

FIELD LOSS THRESHOLD

(P.512).

Possible causes:

Motor field winding not connected or open circuit.

Blown field supply fuse(s).

Blown AC line fuse(s).

Field supply failure.

Disconnected, loosely connected or damaged wiring harness.

Improper field loop tuning.

Advertising