Rockwell Automation WebPak 3000  DC Drives Hardware Reference, Installation and Troubleshooting User Manual

Page 82

Advertising
background image

A-4

WebPak 3000 DC Drive Hardware Reference

Drive Input/Output Specifications

The following sections describe drive inputs and outputs. Refer to section 2 for terminal strip
connections and wiring diagrams.

Logic Inputs

ATTENTION: Connecting an external power source to any of the +24 volt
connections (terminals 1, 7, 11, and 14) on the regulator board terminal strip will
damage the drive. DO NOT connect the external power source to the +24 volt
connections on the regulator board terminal strip. Failure to observe this precaution
could result in damage to, or destruction of, the equipment.

The logic input circuits can be powered either from the internal +24 V DC power supply or from
an external +24 V DC power source. The internal +24 V DC power supply is available at the
regulator board terminal strip (see Figure 2.8b). If an external power source is used, only its
COMMON must be connected to 24V COM on the regulator board (terminal 15). 24V COM is
internally not grounded, but may be externally grounded if required by the users control wiring.

Electrical Specifications:
Input Voltage ...................................................................................................... +24 V DC
Turn On Voltage .......................................................................................................... 8 V
Turn Off Current ..................................................................................................... 0.5 mA

Common............................................................ All input circuits have the same common.

Logic Outputs:

The logic output circuits are normally open (when de-energized) relay contacts. When
energized (contacts closed), the three circuits indicate the following drive conditions:

Running 27 to 28,

Alarm

29 to 30,

No Fault

31 to 32

Electrical Specifications:

Operating Voltage ................................................................ 250 V AC maximum

30 V DC maximum

Switching Current ............................................................ 2 A maximum resistive

1 A maximum inductive

Analog Inputs:

The three customer analog inputs are

Manual Mode Reference

Automatic Mode Reference

DC Tachometer Feedback.

These inputs are converted at 12 bits plus sign at their full range. The electrical specifications
for each of these is listed below.

Electrical Specifications:
Current loading...................................................................................... . 2.5 mA maximum

Manual Mode Reference:

Jumper J19

Potentiometer 5 kohm minimum

POT

External Voltage Source: +/- 10 VDC (when used for Analog Trim Ref. )

0 - 10 VDC (when used for Manual Mode Speed Ref.)

EXT

Automatic Mode Reference:

Jumper J12

Jumper J10

Voltage Reference

+/- 10 V DC

VOLTS

VOLTS & PARK

Current Reference

4-20 milliamps

MAMPS

4-20

& PARK

10-50 milliamps

MAMPS

10-50

& 4-20

Advertising