IDX BMS User Manual

Page 48

Advertising
background image

User Guide for Battery Management System Ver4.2

Page 48/75

IDX Company, Ltd.

ADJ

This checkbox is used to enter a battery user ID and specify discharge settings. Selecting this checkbox

will make the corresponding USER ID and Term Volt/Discharge Load fields editable. Selecting the

checkbox again will display the confirmation screen and by selecting

“ yes” will apply the entered settings

to the hardware.

Battery User ID

Optional character string that can be stored in the battery. The USER ID provides a simple means for

identifying each battery. You can set a character string consisting of up to five single-byte alphanumeric.

Charge Voltage

This data is displayed only when the battery is charging. The current charge voltage is indicated.

Charge Current

This data is displayed only when the battery is charging. The current charge current is indicated.

Discharge Term Volt

The termination voltage is indicated. You can enter a desired value with the Change checkbox selected.

This will become the voltage at which discharge will be terminated (setting range: 10.0 to 13.5 V).

Discharge Load

The power output is indicated. You can enter a desired value with the Change checkbox selected. This will

become the power output during discharge (setting range: 13 to 40 W)

You can also access the following function buttons.

Last Data of Discharge (F1)

This button becomes selectable when a channel connected to a battery is selected. Clicking this button will

open the Diagnostic screen of the selected battery. For the Diagnostic screen, refer to CHAPTER 11.

Data Archive (F2)

This button becomes selectable when a channel connected to a supported battery is selected. Clicking this

button will open the Data Archive screen of the selected battery. For the Data Archive screen, refer to

CHAPTER 12 Data Update.

Data Update (F3)

Clicking this button will refresh the list and obtain the latest status data from the hardware.

Battery Setup (F4)

This option is highlighted when a supported battery is connected to the channel. A user selected

name or ID can be stored in the battery. The Battery User ID provides a simple means for

identifying each battery.

When this button clicked, The following dialogs are displayed

Advertising