14. Date of First Full Charge

Date of the first full charge

15. Discharge Record

Record of the last three discharges (date of discharge, maximum

discharge load, discharge time, maximum temperature)

16. Charge Record

Record of the last three charges (date of charge, maximum charge

current, charge time, maximum temperature). Because the date of the

first full charge is shown in Date of First Full Charge, it is not included

in this data.

17. No. of Over Discharges

Number of over-discharges (date of over-discharge, minimum voltage).

This data is recorded when the voltage of a single cell has dropped to

2.3 V or below. Therefore, depending on the deterioration condition of

a given cell this data may be recorded even when the overall voltage of

the battery pack is 9.2 V or above.

18. No. of High Loads

Number of times the battery was used at a high load (date of use,

discharge load, voltage, maximum current, temperature). This data is

recorded when the power output at the maximum load current is 50 W

or above.

19. Lowest Temp.

The battery

’s lowest operating temperature and the date on which it

was recorded

20. Highest Temp.

The battery

’s highest operating temperature and the date on which it

was recorded

21. Adaptor Name

Name of the hardware device in use at time of data load

22. Adaptor Ver.

Version of the hardware device in use at time of data load

23. Data From

Display where the data is read from.

Database: read from database

File: read from files

Channel names: read from i-Trax charger

USB-n : read from BMS-VR

24. Graph Image

Graphical representation of the discharge curve (change in voltage as

a function of time).

25. Datebox

Button for switching on/off the items in the Databox (items A to G).

26. Time(min) Voltage(V)

Time and voltage corresponding to the position of the mouse pointer in

the graph.

27. Initial Save

Save displayed graph image as a first data.

28. Initial Graph

Graph data saved from the initial save is displayed with the current

graph by arranging them together.

A. User Ref.

You can enter and display a desired management number for the data

obtained (using up to 20 single-byte alphanumeric).

B. Battery Model

Model of the battery. Users may also enter a desired model code for

those batteries that are not supported by the BMS (using up to 12

single-byte alphanumeric).

C. Ser. No

Serial number of the battery

Advertising