IDX BMS User Manual

Page 66

Advertising
background image

User Guide for Battery Management System Ver4.2

Page 66/75

IDX Company, Ltd.

Selecting a battery in the DataBase screen and then clicking the Archive button will open the Data Archive

screen (shown below) of the selected battery

a. Battery Model:

Model of the battery

b. Ser.No:

Serial number of the battery

c. Lot.No:

Lot number of the battery

d. Battery User ID:

User battery ID of the battery

e. Number of Cycles:

Number of charge cycles as of the moment the data was last saved

f. Capacity:

The current capacity as of the moment the data was last saved

g. No. of Over Discharges:

A record of over-discharges ins displayed in a chronological order

h. Discharge Capacity History:

A record of discharge capacities is displayed in a chronological order

i. Highest Temp.:

A record of the battery’s highest temperatures is displayed in a

chronological order

j. No. of High Loads:

A record of usage under high loads is displayed in a chronological order

k. Discharge History:

A record of the battery

’s discharges is displayed in a chronological order

l. Lowest Temp.:

A record of the battery’s lowest temperatures is displayed in a

chronological order

m. Charge History:

A record of the battery’s charges is displayed in a chronological order

n. Close:

Clicking this button twill close the Data Archive screen and the program

will return to the Database screen.

a

b

c

d

e

f

g

i

k

l

m

n

h

j

Advertising