User Guide for Battery Management System Ver4.2

Page 55/75

IDX Company, Ltd.

3) Battery data after the second full charge

* The screen displays charge data in the order in which it was obtained,

beginning with the most

recent data shown at the top

.

* Because the date of the first full charge is recorded in Date of First Full Charge, the charge data

shown in Charge Record applies to

the second charge and onward

.

* In relation to Number of Cycles, the BMS

counts as one cycle any charge that takes place after a

continuous discharge of 10% or more of the current capacity

.

5.

Necessary conditions for the recording of Charge and Discharge Data

1) Discharge data

The system will record data of all continuous discharges of one minute or more with a load of 3 W or

above. To enable correct recording, the load must be removed after each discharge.

2)Charge data

Data will be recorded after a full charge.

* Only the three most recent charges (or discharges) can be recorded in the battery or BMS-VR. Recording

the fourth charge (or discharge) will overwrite the data of the oldest charge (or discharge).

A record of the second charge is

shown in Charge Record.

Cycles are counted in Number of Cycles.