3.04 Gas Connections

A. Connecting Gas Supply to Unit

Use only compressed air with this power supply.

An in-line pneumatic dryer & evaporator type air filter, capable of filtering to at least 5 microns, is required when using air from a
compressor. This type filter will insure that moisture, oil, dirt, chips, rust particles, and other contaminants from the supply hose
do not enter the torch. For highly automated applications, a refrigerated drier may be used.

The connection is the same for compressed air from a compressor from high pressure cylinders. Refer to subsection 3.4-B or 3.4-
C if an additional air line filter is to be installed.

1. Connect the air line to the inlet port. The illustration shows typical fittings as an example. Other fittings can be

used.

NOTE

For a secure seal, apply thread sealant to the fitting threads, according to manufacturer's instructions. Do not use
Teflon tape as a thread sealer, as small particles of the tape may break off and block the small air passages in the torch.

Art # A-02999

Hose Clamp

1/4 NPT to 1/4"

(6mm) Fitting

Regulator/Filter
Assembly

Inlet Port

Gas Supply
Hose

Bowl

Air Connection to Inlet Port