Tweco 51 with SL100SV CutMaster User Manual

Page 87

Advertising
background image

Manual 0-4640

5-23

SERVICE

5

F. Gas flows; No arc in torch; AC

, GAS

, and DC

indicators ON; TEMP indicator off

1. Faulty IGBT

a. Measure between the following points on the Main PC Board:

• E4 to E10

• E10 to E20

Voltage should be approximately 20 vdc before the start signal is active. If voltage measures greater than 100 vdc

when the start signal is active, replace the IGBT.

Art #A-04220

IGBT

Output

Diode

E4

E20

E10

Main PC Board Layout (IGBT Test Points)

Advertising