Tweco 51 with SL100SV CutMaster User Manual

Page 81

Advertising
background image

Manual 0-4640

5-17

SERVICE

5

G. Gas continues to flow with RUN / RAPID AUTO RESTART / SET switch in RUN position.

1. Damaged gas solenoid.

a. Turn the front panel ON/OFF switch to OFF.

• If gas continues to flow, debris from the air line is preventing the solenoid from closing. Clean or replace the solenoid.

2. Faulty RUN / RAPID AUTO RESTART / SET switch.

a. Put switch in SET position. Disconnect wire harness connector from Main PC Board receptacle J18. Check continuity

through wire harness sockets 7 and 8. If no continuity, replace switch.

Art #A-03751