INSTALLATION

3-14

Manual 0-4640

3

5.

Connect the wire harness from the alternate CNC Control to the 20-position terminal strip (labeled 'J2') on the Automation
Interface PC Board. Refer to the illustration.

a. For divided voltage output, connect to terminals J2-11 (negative) and J2-9 (positive).

b. For raw arc voltage, connect to Main Power PC Board terminals E24 (negative) and E27 (positive). Refer to the

illustration on the next page.

NOTE

There is no need to disconnect the factory-installed wire harness from the J4 terminal strip.

3

9

5

4

1

2

6

7

8

10

13

19

15

14

11

12

16

17

18

20

Art # A-04393

To

rch Switch

(P

ositiv

e)

Torch Switch (Negativ

e)

OK to Mo

ve

OK to Mo

ve

Divided Output (P

ositiv

e)

Divided Output (Negativ

e)

Logic Common

Open

Open

Open

Open

Open

Open

Open

Open Arc

Volts - P

ositiv

e (Propr

ietar

y)

Arc

Volts Negativ

e - (Propr

ietar

y)

Remote Current Control (Optional)

Remote Current Control (Optional)

Remote Current Control (Optional)

To Main PC Board
Terminal J27-3

To Main PC Board
Terminal J27-1

To Main PC Board
Terminal J27-2

Installed only with

Optional Remote Current Control

Terminal Block J2

Automation Interface PC Board

Alternate CNC Controller Connections to Automation Interface Board

6.

Tighten the through-hole protector ('strain relief') to secure the CNC cable to the power supply. Leave the factory-
installed harness connected to terminal block J4 in place.

Advertising