Manual 0-4640

5-31

SERVICE

5

D. Main Input Power Test

WARNING

The following tests must be performed with the power supply connected to primary input power. There are extremely
dangerous voltage and power levels present inside this unit. Do not attempt to diagnose or repair without proper
training in power electronics measurement and troubleshooting techniques.

Reconnect power and observe proper start-up procedure. AC indicator on the Front Panel should be ON. If indicator is OFF there
is no voltage to the Power Supply or an overvoltage condition exists.

1. If AC indicator on Front Panel is OFF, check for proper AC input voltage between input cables on the Main Contactor.

Input voltage should be as shown in the following chart. If not, check for proper voltage at the main power source.

Input

Power

Test Points

Voltage

Range

208/230V

L1, L2

187-253VAC

400V

L1, L3

360-440VAC

460V

L1, L3

414-506VAC

CutMaster 51 Input Contactor Voltage Ranges

A-03224

Main Contactor

L1 L2 L3

T1

T2

T3

To E3

Connections to

Main PCB

To E1

To E2

Input Side

Label

#11

#12

L3

L2

L1

A-03223

Input
Cable (L1)

Input
Cable (L2)

Label

Wire #11

Wire #12

Main Input Contactor (460-Volt Three-Phase Input Power Shown) 208/230-Volt Main Input Contactor

2. Check for approximately 28 VAC on coil of contactor between wires # 11 and #12.

a. If voltage is correct, replace main contactor. If voltage is incorrect, replace Main PC Board.