D. AC

and TEMP indicators ON, fan does not run

1. Air flow through unit is restricted

a. Provide adequate air flow

2. Exceeded Duty Cycle of Power Supply

a. Deactivate torch and wait for fan to cool unit. Refer to Section 2 for proper duty Cycle for this unit.

3. Faulty Fan

Measure for 230 VAC (±) on the Main PC Board from J26-1 to J26-4.

• If voltage is correct, replace Fan (M1).