Tweco 51 with SL100SV CutMaster User Manual

Page 82

Advertising
background image

SERVICE

5-18

Manual 0-4640

5

3. Faulty Logic PCB.

a. Measure for approximately 12 vdc between P1-7 and TP-1 on the Logic PCB.

• If 0 vdc is present, replace Logic PCB.

Art # A-03883

TP6

D8

TP1

TP8

TP9

TP10

TP3

TP4

TP2

TP5

TP7

P1-1 to P1-36

P1-7

Logic Board Layout

Advertising